Scales
CAS PDN Scale — USB Setup Guide
User manual: CAS-PDN-User-Manual (1).pdf
Requirements
- CAS PDN series scale with USB B-Type port
- USB A-to-B cable connected to the Android POS device
- SmartOn POS app ≥ 1.4.16 with Enable USB Scale toggled on in Settings
Scale Configuration
The scale must be configured once via its built-in Setup Mode before first use.
Entering Setup Mode
- Power the scale off
- Hold the ZERO key and press the power switch — display shows U SEt
- Navigate with ZERO (moves to next setting)
- Change a value with TARE
- Press ZERO to save and advance to the next category
Category 1 — USB ECR Type
Navigate to Category 1 and press TARE until the display shows typ 14, then press ZERO to save.
Why Type 14? Types 0–12 use a request-response protocol — the cash register must actively poll the scale. Type 14 streams weight data continuously so the Android app reads it passively without sending any commands.
Category 2 — RS232 Communication Mode
This category controls the RS232 port only and has no effect on USB communication. Leave it at the factory default.
Android App Setup
- Open Settings in the SmartOn POS app
- Enable the USB Scale toggle — the app will require a restart
- Restart the app
- Plug the scale into the Android device via USB — tap Allow when the permission dialog appears
- To verify: go to Settings → Test Scale (read weight), place an item on the scale and confirm the weight appears
Usage in the POS
Once the scale is connected and enabled, place the cursor in any input field in the web app, then put an item on the scale. When the reading stabilises the weight is automatically typed into the focused field.
Troubleshooting
| Symptom | Likely cause | Fix |
|---|---|---|
| Scale detected but no weight is read | Wrong USB ECR type set on the scale | Enter Setup Mode → Category 1 → set to typ 14 |
| Scale not detected at all | USB permission not granted | Unplug and replug the USB cable, tap Allow when prompted |
| Weight reads but field doesn't fill | No input field focused | Tap the input field first, then place the item on the scale |
| Weight value is 10× too high or too low | Scale resolution mismatch | Check that the scale display matches the value shown in the app test screen |
| App asks for USB permission on every boot | Normal Android behaviour for USB host devices | Tap Allow — permission persists until the app is reinstalled |